TriCaster
Works, untested. TriCaster’s DataLink keys show live values in title pages, also while they are on air: ScoreSight sets one key per field over TriCaster’s HTTP API. Or show a ScoreSight browser overlay in a Live Link web buffer.
On this page
DataLink keys in title pages
-
In ScoreSight, select HTTP API in the Outputs list (Outbound HTTP API) and pick TriCaster DataLink in Preset. The URL becomes:
http://admin:admin@TRICASTER-IP/v1/datalink?key={field}&value={value} - Replace
TRICASTER-IPwith the TriCaster’s IP address, andadmin:adminwith its login if you changed it. (ScoreSight uses Basic or Digest authentication, whichever the TriCaster asks for.) - Tick Send out API requests to external services. ScoreSight now sends
GET /v1/datalink?key=Home%20Score&value=21and so on: one request per changed field, at most 10 per second. - In a TriCaster title, type
%in a text line and pick the key: each field is a DataLink key named exactly like the field, so%Home Score%shows the Home Score field and%Time%the clock. The HTTP API page lists the keys (DataLink keys: %Home Score%, %Time%…). A fallback for an empty key:%{Home Score, "0"}%.
To check: open http://TRICASTER-IP/v1/datalink in a browser; it lists the DataLink keys and their values.
Unverified: whether DataLink accepts keys with spaces over HTTP. If %Home Score% stays empty, tick Letters, digits and _ only on the HTTP API page and use %home_score%. The highest update rate TriCaster accepts for titles on air isn’t documented: lower Rate if updates lag.
Browser overlay in a Live Link buffer
- In ScoreSight, select HTTP server in the Outputs list, set up an overlay under Browser overlays with the computer’s network address, and click Copy.
- On the TriCaster, hover one of the first 10 buffer slots, click + to open the Media Browser, and choose Web Browser (Live Link).
- Paste the overlay address, for example
http://192.168.1.20:18099/overlay/scorebug. - Use the buffer in a DSK or as a key source.
Live Link needs a recent TriCaster software revision (Vizrt’s partners cite Rev 7–9 or later). The rendered page keeps its alpha. Untested: how often the buffer refreshes on air.
DataLink watch folder (untested idea)
A DataLink watch folder reads key=value text files. ScoreSight’s Text files output can write one (Save key=value .txt file: results.txt), but the watch folder also sees the per-field .txt files, which have no =. Prefer the HTTP route above.
Vendor documentation
- TriCaster Automation and Integration Guide (DataLink, HTTP commands, password protection)
- Live Link